Our library is the biggest of these that have literally hundreds of thousands of different products represented. easily to access, read and get to your devices. This ebooks document is best solution for you. A copy of the instructions for digital format from original resources. Using these online resources, you will be able to find just about any form of manual, for almost any product.

Additionally, they are entirely free to find, so there is totally free (read cloudamericainc-library.com: privacy policy). File Name Size Status.pdf 56543 KB AVAILABLE Click the button or link below to register a free account.

1 Manufacturer: KAESER KOMPRESSOREN GmbH Coburg PO Box 2143 GERMANY Tel. 52 6 Installation 6.5 Connecting the Condensate Drain 1. The power supply must only be connected by authorised installation personnel or an authorised electrician. Carry out safety measures as stipulated in relevant regulations (IEC 364, for example or DIN VDE 0100) and in national accident prevention regulations (BGV A3 in Germany). In addition, observe the regulations of the local electricity supplier. Test the overcurrent protection cut-out to ensure that the time it takes to disconnect in response to a fault is within the permitted limit.

Kaeser Compressors Manuals

Select supply cable conductor diameters and fusing in accordance with local regulations. The user must provide the machine with a lockable power supply disconnecting device. This could be, for example, a load disconnect switch with fused input. If a circuit breaker is used it must be suitable for the motor starting characteristics. Check that the tappings on the control voltage transformer are connected according to the supply voltage.

If not, change the tappings to suit the power supply voltage. Danger of fatal injury from electric shock! Switch off and lock out the power supply disconnecting device and verify the absence of voltage.

Connect the machine to the power supply. Ensure that the cabinet again complies with the requirements of degree of protection IP54.

Kaeser Compressor Parts Manual

Further information The electrical diagram in chapter 13.4 contains further details of the power supply connection Option T2 Refrigeration dryer: Connecting the transformer according to the mains supply. The refrigeration dryer transformer has tappings for various mains voltages.

Manual

Kaeser Compressor Service Manual

Check that the correct connections are made for the supply voltage provided for the machine. If necessary, re-connect the transformer to match the mains supply voltage. Further information The electrical diagram in chapter 13.4 contains further details of the power supply connection. 6.5 Connecting the Condensate Drain A threaded hose connection is provided to connect a condensate drain hose to the condensate drain outlet. Condensate must be able to drain freely.

The illustration shows typical installations. Condensate flows downward in the collecting line. This prevents condensate flowing back to the compressor.